![[Fixed type] Toxic Gas Detectors](/en/gas/product/images/ttl_01.gif)

TX-FH
- 2 wire transmitter
- Analog display
- Using remote type sensor
- With digital display (FH-D)
- Without display (FH-N)


TX-FMD
- 2 wire transmitter
- Digital Display
- Using GS-DX/DY type sensor
- With analog display (FM)
- Without display (FN)


TX-DP-A
- 2 wire transmitter
- Analog display
- Using GS-DP type plug in sensor
- With digital display (DP-D)
- Without display (DP-N)


TX-EP-A
- 2 wire transmitter
- Analog display
- Using GS-EP type plug in sensor
- With digital display (EP-D)
- Without display (EP-N)


TX-MD-D
- 2 wire transmitter
- Digital Display
- Using GS-MD type plug in sensor
- With analog display (MD-A)
- Without display (MD-N)


STX-PA
- Smart type
- LCD display (Gas name & concentration)
- Local visual alarm
- Alarm relay contacts SPDT x 2
- Alarm relay contact SPDT x 1
- Remote type sensor


STX-PA-NRD
- Smart type
- LCD display (Gas name & concentration)
- Local visual alarm
- Alarm relay contacts SPDT x 2
- Alarm relay contact SPDT x 1
- Non-remote type GS-DP sensor


STX-PA-NRE
- Smart type
- LCD display (Gas name & concentration)
- Local visual alarm
- Alarm relay contacts SPDT x 2
- Alarm relay contact SPDT x 1
- Non-remote type GS-EP sensor


TX-3350ExP-E-D For GS-EP sensor
- 2 wire transmitter
- Digital display
- Using GS-EP type plug in sensor
- Ex-proof type


SH-1000HT-D
- LED Display
- Built in system status function
- Same compact size for NF3, PFC detecting
- DC24V Operation
- Using GS-HT-J/ET-J sensor
- - Both on & off site calibration
- Optionally available following models
- With replay SH-1000HT-R


SH-1000GT
- Analog display
- Built in system status function
- Same compact size for NF3, PFC detecting
- DC24V Operation
- Using GT-H/E sensor
- - Both on & off site calibration


SH-1400TW-FL
- Analog display
- Same compact size for NF3, PFC detecting
- DC24V Operation
- Using GS-HX/HY/EP sensor


SH-1000PA
- Stand-Alone Gas detection system
- LCD display (Gas name & concentration)
- DC 4-20 mA output
- Local audio & visual alarm
- Alarm & error relay contacts
- AC 100-240V operation
- Using By-pass flow - Quick detecting System status
- Disconnect sensor
- Low electrolyte level of sensor
- Lose of sample flow
- Filament failure
- Using GS-HY/EP sensor


SH-4600IR
- N2O 0-300 ppm (Alarm point 50ppm)
- LCD display
- Local audio/visual alarm
- Alarm and error relay contacts
- Wall mount type
- AC100-240V operation


SH-4700IR
- CF4 0-500 ppm (Alarm point 100ppm)
- LCD display
- Local audio/visual alarm
- Alarm and error relay contacts
- Wall mount type
- AC100-240V operation


SH-4500IR
- SF6 0-1000 ppm (Alarm point 200ppm)
- LCD display
- Local audio/visual alarm
- Alarm and error relay contacts
- Wall mount type
- AC100-240V operation


TG-XTM-A
- Using GS-HS/ES sensor
- LCD display
- Local visual alarm
- Alarm and error relay contacts
- Panel mount type
- AC100-240V operation


TG-TEB
- Using GS-HS/ES sensor
- LCD display
- Local visual alarm
- Alarm and error relay contacts
- AC100-240V operation


Mini-BA
- Using GS-HS/ES sensor
- LCD display
- Local visual alarm
- Alarm and error relay contacts
- AC100-240V and rechargeable battery operation


TG-4600TEB-IR
- N2O 0-300 ppm (Alarm point 50ppm)
- LCD display
- Local visual alarm
- Alarm and error relay contacts
- AC100-240V operation


TG-4700TEB-IR
- CF4 0-500 ppm (Alarm point 100ppm)
- LCD display
- Local visual alarm
- Alarm and error relay contacts
- AC100-240V operation


TG-4500TEB-IR
- SF6 0-1000 ppm (Alarm point 200ppm)
- LCD display
- Local visual alarm
- Alarm and error relay contacts
- AC100-240V operation


TG-2100TEB-IR
- IPA 0-2% monitor
- LCD display
- Local visual alarm
- Alarm and error relay contacts
- DC24V operation